| Description
| Features | Specifications
| Electroline Advantage | PDF
Fact Sheet |
SuperTap
Specifications:
General
Specifications:
Available tap and coupler values:
|
Model
|
2-port
(dB) |
4-port
(dB) |
8-port
(dB) |
Coupler
Value (dB) |
| 4 |
8 |
12 |
0 |
| 8 |
12 |
15 |
3 |
| 12 |
15 |
18 |
7 |
| 14 |
18 |
21 |
10 |
| 16 |
20 |
23 |
12 |
| 18 |
21 |
25 |
14 |
| 20 |
23 |
27 |
16 |
| 21 |
25 |
29 |
18 |
| 23 |
27 |
31 |
18 |
| 25 |
29 |
33 |
18 |
| 27 |
31 |
35 |
18 |
| 29 |
33 |
37 |
18 |
| 31 |
35 |
39 |
18 |
RF Specifications
(all models)
RFI shielding: 100 dB min.
Isolation (dB min.):
|
|
Frequencies
(MHz)
|
|
7-15
|
15-450
|
450-600
|
600-862
|
862-1000
|
|
Tap-Tap
Isolation dB
|
25
|
25
|
23
|
17
|
17
|
|
On/Off
Isolation dB
|
55
|
55
|
55
|
50
|
50
typ./45 min
|
AC
Specifications
Power Passing (In to Out port current): |
| 10
A max. at 60 Hz |
90
Vrms (quasi square wave)
76 Vrms (sinusoidal wave) |
| Operating
Voltage Range: |
28
- 90 Vrms (quasi square wave)
24 - 76 Vrms (sinusoidal wave) |
| Typical
Power Consumption: |
|
|
Sinusoidal
wave
|
Quasi
square wave (rms)
|
|
25mA
@ 24Volts
|
16mA
@ 28 Vrms
|
|
30mA
@ 42Volts
|
23mA
@ 50 Vrms
|
|
42mA
@ 76Volts
|
35mA
@ 90 Vrms
|
| Operating
temperature range: |
-40°F
to 140°F / -40°C to 60°C |
| Mechanical
Specifications: |
|
| Dimensions: |
5
1/8" X 5 9/32" X 3 3/8"
130 mm X 134 mm X 86 mm |
| Weight: |
1.94
lb (0.88 kg) |
For
further information, contact Electroline's Sales & Marketing Department
using our Online Information Request
Form.
Control
Unit IV
- CAT Addressable Splitter - CAT-Agile Decoder - SuperTap - SuperTap Agile ULTIMA Series Addressable Tap - RetroPlate
-
ANEX Tap
- LoopTap
System - SoftConnect - Reporter
Addressable
Products - Return
Path Products - Amplifiers
- Line Passives RF Signal Management - Network Status Monitoring Transponders
|