| Description
| Features | Specifications
| Electroline Advantages | PDF
Fact Sheet |
The
Electroline ReturnPath Amplifier (ERA) Specifications, RF
Specifications:
| Forward
Passband |
54-1000
MHz |
|
| Return
Passband |
5-42
MHz |
| Return
Path Gain (5-42 MHz) |
10
± 1 dB |
| Forward
Insertion Loss |
1.5
dB (max.) |
| Return
Loss |
18
dB |
| 1
dB Compression Point1 |
+
74 dBmV |
| Return
Path Distortions
Second
Order2
Third Order3
|
-
75 dBc
- 60 dBc |
| Forward
Path Distortion4 |
-
50 dBmV (max.) |
| Noise
Figure |
5.5
dB |
Return
Path Group Delay
(1 MHz span)
7-36
MHz
5-42 MHz
|
5
ns (max.)
12 ns (max.) |
Forward
Path Group Delay
(3.58 MHz span)
Channel
2
Channel 3
Other Channels
|
25
ns (max.)
10 ns (max.)
5 ns (max.) |
|
|
| Hum
Modulation |
-
70 dBc |
| RFI
Isolation |
100
dB (min.) |
PWR
to RF IN Isolation
(5-42 MHz) |
100
dB (min.) |
| Surge
Protection |
6
kV (all ports)
C62.41-1991 ring wave, loc.A3 |
Recommended
Wall Adapter
Output Rating |
18
VDC 300 mA
PTC short-circuit protection |
| Operating
Temperature |
-40°C
to +60°C |
| F
Connector Type |
SCTE
IPS-SP-400, water sealed |
|
Notes:
- Measured
after amplification
- Second
order distortion is measured at 12 MHz with three carriers (19, 25,
31 MHz), each adjusted to 60 dBmV after amplification
- Third
order distortion is measured at 37 MHz with three carriers (19, 25,
31 MHz), each adjusted to 60 dBmV after amplification
- Distortion
is measured at 56 MHz with three carriers (19, 25, 31 MHz), each adjusted
to 60 dBmV after amplification
For further
information,
contact Electroline's Sales & Marketing Department:
Email: Use our Online Information
Request Form
Tel.: (514) 374-6335 (Toll-free: 1-800-461-3344)
Fax: (514) 374-9370
8265 St-Michel Blvd.
Montréal, QC, Canada, H1Z 3E4
Drop
Amplifier (EDA) - Return Path Amplifier (ERA) EDA-UG
- EDA-EQ 3100 - EDA Flat-Top
Addressable
Products
- Return Path Products - Amplifiers
- Line Passives RF Signal Management
- Network Status Monitoring Transponders
|